CP-Al2O3
CP-Al2O3 PLOT GC Columns from Agilent Technologies
Agilent J&W Aluminum oxide PLOT columns offer high selectivity for separating ppm levels of C1-C5 hydrocarbons in process streams. These columns analyze more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. Choice of two selectivities covers a broad range of applications
- CP Al2O3/KCl has an apolar surface to separate ppm levels of C1-C5 hydrocarbons in a main stream of C1-C5 hydrocarbons
- CP Al2O3/Na2SO4 has a polar surface to separate ppm levels of C1-C5 hydrocarbons in a main stream of C1-C5 hydrocarbons.
All pictures shown are for illustration purpose only. Actual product may vary.
- Buy
- Features
-
CP-Al2O3/KCl GC Columns
Agilent J&W CP-Al2O3/KCl is an aluminum oxide PLOT column that offers high selectivity for separating ppm levels of C1-C5 hydrocarbons in a main stream of C1-C5 hydrocarbons. The KCl deactivation salt results in relatively apolar Al2O3 surface. These columns analyze more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, CP-Al2O3 provides increased selectivity and allows all C1-C5 hydrocarbon isomers to be separated. CP-Al2O3 operates without the need for sub-ambient cooling.- The KCl deactivation salt results in a relatively apolar Al2O3 surface
- High capacity thick films
- No need for sub-ambient cooling simplifies operation
- Available in Fused Silica and UltiMetal
Similar Phases: Al2O3/KCl, Rt-Alumina PLOT, Alumina PLOT, RT-Alumina BOND/KCl, Alumina chloride PLOT, AB-PLOT Al2O3 KCl
CP-Al2O3/Na2SO4 GC Columns
Agilent J&W CP-Al2O3/Na2SO4 is an aluminum oxide PLOT column that offers high selectivity for separating ppm levels of C1-C5 hydrocarbons in a main stream of C1-C5 hydrocarbons. The Na2SO4 deactivation salt provides a polar Al2O3 surface, so that unsaturated compounds such as ethylene and acetylene are retained longer. These columns analyze more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, CP-Al2O3 provides increased selectivity and allows all C1-C5 hydrocarbon isomers to be separated. CP-Al2O3 operates without the need for sub-ambient cooling.- The Na2SO4 deactivation provides a polar surface. Unsaturated compounds such as ethylene and acetylene (ethyne) are retained longer.
- High capacity thick films
- No need for sub-ambient cooling simplifies operation
- Available in Fused Silica and UltiMetal
Similar Phases: Al2O3/Na2SO4, Rt-Alumina PLOT, Alumina PLOT, Rt-Alumina BOND/Na2SO4, MXT-AluminaBOND/Na2SO4, Alumina sulfate PLOT
- Specifications
-
CP-Al2O3/KCl Temperature Specifications
ID (mm) 0.25 – 0.32 mm 0.53 mm Length (m) 10 – 50 m 25 – 50 m Film (µm) 4.00 – 5.00 µm 10.00 µm Temperature Limits (°C) –100 – 200/200 °C –100 – 200/200 °C CP-Al2O3/Na2SO4 Temperature Specifications
ID (mm) 0.25 – 0.32 mm 0.53 mm Length (m) 10 – 50 m 25 – 50 m Film (µm) 4.00 – 5.00 µm 10.00 µm Temperature Limits (°C) –100 – 200/200 °C –100 – 200/200 °C - Literature
-
-
Agilent GC Column Brochure
Full range of Aglient Technologies GC columns and applications
-